3.3 Electro-acoustic Performance Indexes
3.3.1 The electro-acoustic performance indexes of PAS in every service zone shall be in accordance with those specified in Table 3.3.1.
Table 3.3.1 Electro-acoustic performance indexes of PAS
*:The ENSPL of emergency broadcast shall meet the requirements stipulated in item 2,article 3.2.5 of this code.
Figure 3.3.1-1 Tolerance domain of indoor transmission frequency response of business announcement class 1/background broadcast class 1
(the maximum value of the measured curve is set to be 0dB)
Figure 3.3.1-2 Tolerance domain of indoor transmission frequency response of business announcement class 2/background broadcast class 2
(the maximum value of the measured curve is set to be 0dB)
Figure 3.3.1-3 Tolerance domain of indoor transmission frequency response of business announcement class 3
(the maximum value of the measured curve is set to be 0dB)
3.3.2 For indoor PAS,the relevant architectural acoustic characteristics should comply with the requirements of current national standards GB/T 50356,Code for architectural acoustical design of theater,cinema,and multi-use auditorium and JGJ/T 131,Specification for acoustical design and measurement of gymnasium and stadium.